Stationary Powder-Filling Machine Model UP02
The biggest and most powerful powder-filling machine,
highly successful worldwide for more than 40 years.
Model UP 02-5
With our most efficient filling machine you can fill directly all powder extinguishers up to 250 kg content.
With its ergonomic design it is
suitable for smaller filling series.
The filter cleaning is done electrically by push button and can be made easily
after each filling process.
Technical Data: Performance: approx. 14 - 19 kg/min. Power consumption: 400 V, three-phase, 50/60 Cy Weight: approx. 200 kg
Dimensions: |
|
Technical Data:
Filling output: |
UP02-5 |
|
6-kg-container |
50 |
pcs./h |
12-kg-container |
30 |
pcs./h |
50-kg-container |
6 |
pcs./h |
250-kg-container |
1 |
pcs./h |
Conveying capacity |
600 |
kg/h |
Storage capacity |
50 |
kg |
Filter range |
1,50 |
mē |
Reversing |
counter air |
|
Blower type |
gas ring compressor |
|
Suction performance |
max. 220 |
mbar |
Motor performance |
1,5 |
kW |
Operating time |
100 % |
ED |
Electric supply |
400 V, 3 Ph, 50 60 Cy |
|
Dimension: W x D |
850 x 1200 |
mm |
H min./max |
2200 / 2700 |
mm |
Weight |
200 |
kg |
Paint |
White (RAL 9010) |
powdercoated |
Working position of powder refilling machine
model UP02-5
|
Filling or Refilling of Extinguishers - P 12 kg The container to be filled is placed onto the lifting table and pressed against the sealing cone of the control funnel when actuating the crank handle. To this effect the container orifice and the centre of the sealing cone have to be aligned towards each other. Then the holding magnets at the fork can be adjusted in away that further containers of same type and size are automatically aligned. Then place the powder storing container or storing sack on to the balance if available and suction the required quantity of powder by means of the suction pipe into the extinguisher to be filled. |
||
Filling of Mobile Extinguisher - P 50 kg For emptying and refilling of larger mobile extinguishing units the lifting device is swung away, and the extinguishing unit up to a size of type P 50 can be placed directly below the control funnel. After that lower the separator until the sealing cone covers the filling orifice. |
|
||
|
Filling of Mobile Extinguisher - P 250 kg If the mobile fire extinguishing units P 100 and P 250 are to be filled, these units we first place most closely to the filling machine. Then crank the powder separator completely upwards to maintain a fall between the connecting flange of the control funnel and the filling orifice. Replace the control funnel with the two knurled nuts by the interchangeable connecting piece (accessory). |
||